|
USA-017501-Grove Orchard Management företaget Kataloger
|
Företag Nyheter:
- Regarding LIN Communication Issues in Master . . . - PEAK-System
However, I'm not receiving the correct ID during transmission The oscilloscope is capturing a same 6-digit number as the ID[0x3f635547] for different ID transmission, and I'm not receiving a reply from the slave Observations: Interestingly, when sending data in publisher mode yields correct ID and data from the slave device in the
- Home: PEAK-System
Hardware and software for CAN LIN bus applications
- Downloads: PEAK-System
Overview of all free downloads from PEAK-System All downloads for hardware and software products from PEAK-System and documents about the company are provided in categories
- Answer to received message - PEAK-System Forum
If you only want to check if a specific ID was received and then, depending on some conditions of real signals want to send a signal or raw CAN, i would recomment to use a RAW CAN Communication in the VBS We could send you a simple sample if you contact us per e-mail support[at]peak-system com
- Software: PEAK-System
PEAK-Trace Splitter The PEAK-Trace Splitter for Windows® 11 (x64 ARM64), 10 (x86 x64) is used to split large trace * trc files into multiple smaller files The supported * trc is a text based trace file format for CAN messages by PEAK-System Download
- id error messages - PEAK-System Forum
Due to the fact that the frame could also be defective in the ID area, you will never know, which original frame was made to an errorframe A simple soulution will be to check the next good frame, because a sender will repeat the CAN frame again, when it was marked as errorframe by one of the CAN nodes
- Tutorial: Fixed device ID channel assignment . . . - PEAK-System
Adapter1 has device id 0x1 and adapter2 has 0x2 The keys are also inserted into the windows registry (Hardware16='0x201,0x1,0' and Hardware15='0x201,0x2,0') I hope that adapter1 is in use if the PCAN_USB dll is called and adapter2 is in use if PCAN_2USB dll is called
- Software: PEAK-System
A list of the software product line from PEAK-System
- PLIN - Simple API Example - PEAK-System Forum
6 Configured the ID 11h and set the Delay to 10 7 Connected to the HW as Master with 19200baud rate 8 Started the Schedule and I receive response from my target device correctly Unfortunately I'm not able to reproduce a similiar behaviur with the API These are the steps I triy to follow from my code: LIN - Register Client LIN_ConnectClient
|
|